Know the air you breathe

AQ1w Monitor Users Guide

Welcome to the AQ1w Indoor Air Quality Monitor Users Guide. Information in this guide helps you understand the measurements taken by your monitor, identify your air quality at a glance, and make remediation decisions when necessary.

If you need to setup your monitor and connect to a Wi-Fi network, start with quick setup for Residential or Commercial mode.

Table of Contents

Overview

Know the air you’re breathing

The airqio™ AQ1w helps you understand the quality of air inside your home or workplace. It continuously monitors several important aspects of indoor air quality and presents the information in an easy-to-understand format.

The airqio™ monitor measures particulate matter, carbon dioxide, volatile organic compounds, nitrous oxides, temperature, and relative humidity.

The airqio™ app lets you view current conditions, see how readings change over time, and review historical data. Whether you’re checking the air in a room, looking for patterns, or evaluating the effect of ventilation and other activities, airqio™ gives you useful information to make more informed decisions.

The AQ1w is designed to make indoor air quality easier to understand. It is an informational monitoring tool, not a medical device, and its readings should not be used to diagnose or treat health conditions.

AQ1w S65 operating right view green

The Air Quality Index

Making air quality easier to understand

Individual sensor measurements are useful, but interpreting several numbers at once can be difficult. The Air Quality Index (AQI) provides a simpler way to communicate air quality by translating pollutant concentrations into an easy-to-understand scale.

AQ1w uses color-coded air quality levels to help you quickly assess conditions. The colors progress from green, indicating good air quality, through increasingly concerning levels to red and purple, indicating very unhealthy or hazardous conditions.

Understanding the levels

The AQI is a worst contaminant scale. This means that your indoor AQI value could be driven by either PM2.5 or TVOCs. For example, an AQI of 70 might be because PM2.5 is 20 – or – it might be that TVOCs are 470. This table shows the air quality categories used by the AQ1w, the associated health risks, recommendations, and contaminant concentrations.

AQILevelHealth RiskRecommendationPM 2.5 (µg/m3)TVOC (ppb)
0-50Good (Green)NoneGood air quality0.0-9.00-220
51-100Moderate (Yellow)Minimal concernDeteriorating air quality9.1-35.4221-660
101-150Unhealthy sensitive (Orange)Some concernYou may choose ventilation35.5-55.4661-1430
151-200Unhealthy (Red)ObjectionsVentilation recommended55.5-125.41431-2200
201-300Very unhealthy (Purple)Major objectionsLimit exposure, ventilation necessary125.5-225.42201-3300
301-500Hazardous (Maroon)Not acceptableAvoid exposure, ventilation required>225.5>3301

How airqio uses the AQI

The U.S. Environmental Protection Agency (EPA) defines the official AQI for outdoor air pollution. Its standard AQI is based on specific pollutants, including fine particulate matter (PM2.5).

NOTE: TVOC measurements are not included in the EPA’s standard AQI. TVOC categories or color indications are AQ1w-specific interpretations based on guidance from German Federal Environmental Agency, the WHO, and the RESET standard for indoor air quality. The AQI is a communication tool and does not represent a complete assessment of every aspect of indoor air quality.

NOTE: NOx is NOT included in the calculation of AQI as there are no accepted guidelines for mapping the NOx index into AQI. Read more about NOx in the Metrics section below.

Metrics

What AQ1w measures

Indoor air quality is influenced by many factors. airqio monitors several key measurements to help you understand what’s happening in your environment.

Particulate Matter (PM1, PM2.5 and PM10)

Particulate matter consists of tiny airborne particles that can be inhaled. The AQ1w measures three particle-size categories:

  • PM1: Particles with a diameter of 1 micrometer or smaller.
  • PM2.5: Fine particles with a diameter of 2.5 micrometers or smaller.
  • PM10: Particles with a diameter of 10 micrometers or smaller.

Common Sources

  • Cooking, frying, and other food preparation
  • Smoke from fireplaces, candles, tobacco, and combustion
  • Dust and other airborne household particles
  • Outdoor air pollution entering through windows and ventilation systems
  • Construction, cleaning, and other activities that disturb dust

Why It Matters

Airborne particles can be inhaled and affect respiratory health. Smaller particles, particularly PM2.5, can penetrate deep into the respiratory system. Monitoring the different particle sizes helps identify changes in particulate pollution and evaluate whether actions such as reducing indoor sources, improving filtration, or ventilating when outdoor air is clean are effective.

TVOC (Total Volatile Organic Compounds)

Volatile organic compounds (VOCs) are gases released by many common materials and products. TVOC represents an overall indication of the level of these compounds detected by the monitor. The AQ1w reports TVOC as a combined measurement; it does not identify individual chemicals.

Common Sources

  • Cleaning products, disinfectants, and air fresheners
  • Paints, adhesives, and solvents
  • Furniture, carpets, flooring, and building materials
  • Personal care products, fragrances, and aerosol sprays
  • Cooking and other household activities

Why It Matters

Elevated VOC levels can indicate the presence of airborne chemicals from indoor products or activities. Some VOCs can cause irritation or other health effects, depending on the compounds and exposure levels. Monitoring TVOC can help identify changes in indoor air conditions and determine whether reducing a potential source or improving ventilation makes a difference.

eCO₂ (Equivalent Carbon Dioxide)

Carbon dioxide (CO₂) is a naturally occurring gas produced by people breathing and by combustion. The AQ1w does not directly measure CO₂. Instead, it uses other measured values and established relationships to calculate an equivalent CO₂ (eCO₂) reading.

Common Sources

Actual indoor CO₂ is primarily produced by people breathing and by combustion appliances. Levels commonly increase in occupied rooms when ventilation is insufficient to replace indoor air.

Why It Matters

The eCO₂ reading provides an indication that may help you recognize changes in indoor conditions associated with occupancy and ventilation. However, because it is an estimated value rather than a direct CO₂ measurement, it should be interpreted as an indicator, not as a definitive measurement of CO₂ concentration or ventilation effectiveness.

NOx (Nitrogen Oxides)

Nitrogen oxides are a group of gases produced primarily by high-temperature combustion. The AQ1w reports an NOx indicator on a scale of 1 to 500. This reading indicates changes in nitrogen oxide levels but does not identify individual gases or provide a direct concentration for a specific compound. When the index is above 20, air quality is deteriorating. When the index is above 50, you might consider ventilating. And, when the index is above 100, ventilating is strongly encouraged.

Common Sources

  • Gas stoves and gas ovens
  • Unvented gas or other combustion heaters
  • Fireplaces and other combustion sources
  • Tobacco smoke and other burning materials
  • Outdoor vehicle emissions entering through windows and ventilation systems

Why It Matters

Nitrogen dioxide (NO₂), one of the most important nitrogen oxides, can irritate the respiratory system and aggravate asthma and other respiratory conditions. Monitoring NOx can help identify changes potentially associated with combustion or outdoor pollution and prompt investigation of possible sources.

Temperature

Temperature measures how warm or cool the indoor environment is. It is an important factor in indoor comfort and can influence how other environmental conditions, such as relative humidity, are experienced.

Common Sources

  • Heating and air-conditioning systems
  • Outdoor weather and seasonal temperature changes
  • Direct sunlight and solar heating
  • Cooking, appliances, and other sources of indoor heat
  • Occupancy and activity within a room

Why It Matters

Temperature affects comfort and can influence indoor humidity and condensation. Monitoring temperature over time helps identify changes associated with heating, cooling, sunlight, and other environmental conditions.

Relative Humidity

Relative humidity (RH) describes the amount of moisture in the air compared with the maximum amount the air can hold at its current temperature. It is expressed as a percentage.

Common Sources

  • Cooking, showering, and bathing
  • Laundry and indoor clothes drying
  • Leaks, damp materials, and moisture intrusion
  • Outdoor humidity entering through ventilation and open windows
  • Heating, cooling, and dehumidification systems

Why It Matters

Humidity that remains too high can contribute to condensation and mold growth. Very low humidity can cause discomfort and dryness. Monitoring relative humidity helps you recognize conditions that may warrant improved ventilation, moisture control, or humidification. A general indoor target is approximately 30–50% relative humidity.

Looking at the measurements together

No single measurement tells the whole story. For example, a room may have low particulate levels but elevated TVOCs, suggesting that ventilation could be improved. Looking at multiple measurements together provides a more useful picture of indoor air conditions.

LED Indications

The airqio monitor uses two LED indicators to communicate air quality and device status.

Air quality indicator (RGB LED)

The multicolor LED provides a quick visual indication of the current air quality level. Its color corresponds to the air quality color scale shown in the Air Quality Index section.

Note that when the monitor is first powered on, the indicator shows white while the sensors warm up. This initial process takes a few minutes.

You may also notice that the RGB indicator occasionally turns off briefly at random intervals, an indication that particulate matter is determining the air quality index level. This intermittent behavior is normal and does not indicate a problem.

Device status indicator (blue LED)

The blue LED communicates the monitor’s connection and sensor status.

Blue LED behaviorMeaning
A short burst of rapid blinking once per secondWi-Fi credentials have not been configured.
Continuous rapid flashingThe monitor is unable to maintain its cloud connection. If the blue LED indicates a Wi-Fi or cloud connection problem, refer to Help and Troubleshooting for steps to restore connectivity.
One brief blink approximately every 10 secondsThe sensor is still converging toward its rated accuracy. This process can take several hours.

Allow time for sensor stabilization

After power-on, the sensors need time to warm up and stabilize. Although the initial warmup takes only a few minutes, some measurements may continue to settle over a period of several hours. During this period, readings may change as the sensors approach their rated accuracy. This is normal operation and does not indicate a problem with the monitor.

Using the airqio App

The airqio app provides a convenient way to view current indoor air quality measurements from your connected monitors. The Monitor tab displays all your monitors together in a vertically scrollable panel, making it easy to check conditions throughout your home or workplace.

Scanning for monitors

When the app first starts, or when the app returns to the foreground, it scans for AQ1w monitors within Bluetooth range. The length of the scan time can be changed in the Settings tab.

When the scan is complete, the app shows the metrics panels for all monitors within range.

The Devices tab shows a list of monitors that are nearby and able to be connected and those that are distant – with low signal strength. To connect to a monitor on the distant list, move closer to the monitor. You can change the minimum RSSI signal strength for connecting to a monitor in the Settings tab. Note that choosing RSSI values less than 80 dBm can cause unreliable communication.

Scanning for monitors

Viewing your monitor readings

Each monitor has its own metrics panel. The panel displays the current readings, including:

  • AQI: The air quality index with the driving metric following the title. The metric panel header color indicates the index category.
  • TVOC: Volatile organic compounds concentration.
  • eCO₂: Carbon dioxide concentration.
  • PM1, PM2.5 and PM10: Airborne particulate matter in different particle-size categories.
  • Temperature: Current indoor temperature.
  • Relative Humidity: The percentage of moisture in the air relative to the maximum amount it can hold at that temperature.
  • NOx: Nitrogen oxides on a scale of 0 to 100.

Each reading includes its measurement units, so you can interpret the values correctly.

Readings are updated as new measurements become available from the monitor, every 15 seconds. Values can change throughout the day as indoor activities, ventilation, and other environmental conditions change.

The metrics monitoring panel

Understanding the Metrics panel

The air quality indicator uses the airqio color scale to provide an at-a-glance assessment. The individual metric values provide more detail and help you understand which aspects of air quality may need attention.

The panel header includes two controls:

  • Settings (gear icon): Opens the monitor’s settings, including the option to assign or change its friendly name.
  • History (circular icon): Opens the History screen for that particular monitor, where you can review its historical readings and trends.
Metrics panel detail

Giving your monitor a friendly name

If you have more than one airqio monitor, assigning each one a friendly name makes it easier to identify its location.

For example, you might name your monitor: Living Room, Kitchen, Office, or some other descriptive name.

To assign or change a monitor’s name:

  1. Find the monitor’s Metrics panel on the Monitor screen.
  2. Tap the gear icon in the panel header.
  3. Enter a descriptive name and save your change.

Choose a name that describes where the monitor is located. This makes it easier to recognize the correct monitor when checking readings, reviewing historical data, or when more than one monitor is connected.

You can change a friendly name whenever you move a monitor or want to identify it differently.

Assigning a friendly name

Monitoring multiple locations

All connected monitors appear on the Monitor screen, each with its own Metrics panel. Scroll vertically to view additional monitors.

This makes it easy to compare conditions in different rooms or areas of your home or workplace.

For example, you may notice that particulate levels rise in the kitchen during cooking, while eCO₂ levels increase in a bedroom overnight. Monitoring multiple locations can help you better understand how indoor air quality varies throughout your space.

History and Data Export

AQ1w doesn’t just show current conditions. The History feature lets you look back at previous measurements and see how your indoor air quality has changed over time.

Viewing historical readings

To open the History screen, tap the History button in the header of the Metrics panel. The History screen offers three views of historical data:

4hr raw: Displays all actual measured sensor values at one-minute intervals for the most recent four hours. This view provides the most detailed picture of short-term changes in your indoor air quality.

24hr trend: Displays averaged readings and maximum values at five-minute intervals for the most recent 24 hours. This view helps you identify daily patterns and periods when measurements reached higher levels.

7 day trend: Displays averaged readings and maximum values at one-hour intervals for the most recent seven days. This view provides a broader perspective on changes and patterns over the course of a week.

The historical data trends includes these measurements from your AQ1w monitor:

  • PM2.5 particulate matter average and maximum during each period
  • Carbon dioxide (eCO₂) average
  • Volatile organic compounds (TVOC) average and maximum
  • Temperature average
  • Relative humidity average
Monitor history panel

Sharing and exporting data

At the bottom of the History screen, when the data table is displayed, tap Share to export the table as a CSV (comma-separated values) file. The CSV file contains the data shown in the currently selected history view. For example, while viewing 4hr raw, the share exports the one-minute readings for that period.

The exported CSV can be saved, shared with another person, or opened in a spreadsheet application for further analysis.

Important: The Share function exports only the data in the table currently displayed. It does not export the monitor’s entire history or allow you to select a custom date range.

Making use of your data

Exported readings can be useful for keeping your own records, examining trends in a spreadsheet, comparing conditions over time, or sharing measurements with someone helping you evaluate your indoor environment.

Monitor history sharing

Help and Troubleshooting

This section covers common questions about setting up your monitor, understanding its readings, resolving connection problems, and improving indoor air quality.

Restarting the monitor should be a last resort. A restart requires the sensors to warm up again and then converge toward their rated accuracy. This can take several hours.

Wi-Fi and Cloud Connection

How do I connect my monitor to Wi-Fi?

Follow the instructions on the AirQio Residential Quick Setup page. This guide walks you through configuring your monitor’s Wi-Fi connection.

My monitor is flashing blue rapidly. What does this mean?

The blue status LED indicates the monitor’s connection status:

  • A short burst of rapid flashes once per second: Wi-Fi credentials have not been configured.
  • Continuous rapid flashing: The monitor cannot connect to the cloud.

If the monitor is not configured, follow the Residential Quick Setup instructions. If it has previously connected, check that your Wi-Fi network and internet connection are working and that the monitor is within reliable Wi-Fi range.

My monitor has lost its cloud connection. What should I do?
  1. Confirm that your Wi-Fi network and internet connection are working.
  2. Make sure the monitor is within reliable Wi-Fi range.
  3. Check whether your Wi-Fi credentials or network settings have changed.
  4. If necessary, follow the Residential Quick Setup instructions to configure the connection again.

Allow the monitor time to reconnect after restoring network access.

Sensor Readings

Why are readings changing after I turn on the monitor?

The sensors require an initial warmup period of a few minutes. Some readings may continue to stabilize over several hours as the sensors converge toward their rated accuracy.

A blue LED blink approximately every 10 seconds indicates that the sensor is still in this convergence period.

Why do my readings fluctuate?

Indoor air quality naturally changes throughout the day. Cooking, cleaning, occupancy, ventilation, open windows, and other activities can affect measurements.

Short-term fluctuations are normal. The 24-hour and 7-day Trend views can help you distinguish longer-term patterns from temporary changes.

Why does the air quality indicator occasionally turn off?

The RGB air quality indicator may occasionally blank briefly when particulate matter is determining the displayed air quality level. This is normal operation and does not necessarily indicate a problem. At a glance, you can determine that PM2.5 is driving your AQI.

Setup and App Troubleshooting

My monitor does not appear in the app.

Check that the monitor is powered on and has completed its startup process – no longer breathing white. Confirm that you are within range and move closer to the monitor – Bluetooth signals may not travel through walls.

Check the Devices tab and see if your monitor is listed as a distant device. If so, you are outside reliable communication range.

There are two Settings that can affect whether your monitor is discovered: Discovery scan time and Minimum RSSI. If the scan time is too fast, your monitor might not be discovered so lengthen the discovery time. You can also set the Minimum RSSI to a lower value to help remediate a distance issue. But be aware that weaker signals can cause communication errors.

The app is not showing updated readings.

The monitor should receive a new reading every 15 seconds. This is indicated by the small blue dot to the left of the device name in the metrics panel header. The dot will be highlighted every time new data is received. If none of the metrics are different than the previous period, there will not be any metric updates.

Make sure you have waited to connect after the RGB LED has changed from white to an AQI color.

Verify that the metrics panel does not show a communication error occurring. If there is a communication error, move closer to your monitor.

Is it ok to move my monitor?

Yes, it is ok to move your monitor to a different space in your residence or building. Just make sure the new location continues to have Wi-Fi access and meets the location requirements.

Moving your monitor requires removing power and then restarting. When restarted, the sensors need to warm up and then converge toward their rated accuracy again. This may take several hours.

Improving Indoor Air Quality

AQ1w helps you identify changes in indoor air quality, but it does not remove pollutants. Improving air quality generally involves identifying and reducing pollution sources, bringing in clean outdoor air when appropriate, and using suitable filtration.

What should I do if particulate matter (PM2.5 or PM10) is elevated?

Particulate matter can come from cooking, smoke, candles, fireplaces, dust, and outdoor pollution. Consider these steps:

  • Use a kitchen exhaust fan that vents outdoors when cooking.
  • Reduce indoor sources such as smoking, candles, and wood-burning fires.
  • Use a properly sized portable air cleaner with an effective particle filter, such as HEPA filtration.
  • Maintain heating and cooling system filters according to the manufacturer’s recommendations.
  • When outdoor air quality is good, ventilation can help reduce indoor particle concentrations.

Watch the airqio readings after taking action to see whether conditions improve.

What can I do if eCO₂ levels are elevated?

Indoor eCO₂ commonly increases when people occupy a room and there is insufficient ventilation. Consider these steps:

  • Increase the supply of outdoor air when outdoor conditions permit.
  • Open windows or doors when outdoor air quality and weather are suitable.
  • Check that mechanical ventilation systems are operating properly.
  • Avoid blocking air supply and return vents.
  • Consider whether the room is occupied by more people than its ventilation system can adequately support.

Note: Typically eCO₂ and TVOCs move together and when one is elevated the other often is as well.

How can I reduce elevated TVOC readings?

TVOCs can be released by cooking, cleaning products, paints, solvents, fragrances, furnishings, and other household materials. Consider these steps:

  • Identify and reduce the use of products that may be contributing to elevated readings.
  • Use paints, cleaners, and other products according to their instructions.
  • Provide adequate ventilation when using products that release fumes.
  • Store chemicals and household products in appropriate, tightly closed containers.
  • Consider whether recently purchased furnishings, flooring, or other materials may be contributing to the readings.
  • When outdoor air quality is good, ventilation can help reduce indoor TVOC concentrations.

Some air cleaners include activated carbon or other gas-phase filtration designed to reduce certain VOCs. Their effectiveness depends on the specific compounds, filter design, and amount of filter material. Particle-only filters do not remove gaseous pollutants.

Why is the NOx reading more than 10, and is this bad?

A reading above 10 simply means the sensor has detected elevated levels of nitrogen oxides compared to your typical baseline clean air. Values over 10 usually point to active indoor or outdoor pollution—such as a gas stove in use, a running space heater,candles, or nearby vehicle exhaust.

Is it bad? Not necessarily for short periods. The index tracks relative events rather than dangerous toxicity thresholds. While a brief bump over 10 isn’t an immediate hazard, prolonged or extremely high spikes mean indoor air quality has temporarily degraded. Running an exhaust fan, or opening a window, may help clear the gas and return the reading to baseline.

When an NOx index reading is above 100, ventilation is strongly encouraged.

What should I do if humidity is too high?

Persistently high indoor humidity can contribute to condensation and mold growth. Consider these steps:

  • Use bathroom and kitchen exhaust fans that vent outdoors.
  • Repair plumbing leaks and other sources of unwanted moisture.
  • Use a dehumidifier when needed.
  • Make sure damp areas and materials are dried promptly.
  • Check that ventilation and air-conditioning systems are operating properly.

A general indoor relative humidity target is approximately 30–50%. Avoid allowing indoor humidity to remain above 60%.

What if indoor air quality is poor even when I ventilate?

Ventilation is not always the answer. Outdoor air can itself contain elevated particulate matter, pollen, smoke, or other pollutants. Check outdoor conditions BEFORE opening windows or increasing outdoor air intake. When outdoor air quality is poor, keeping windows closed and using appropriate indoor filtration may be a better approach.

Also consider whether an indoor pollution source can be eliminated or reduced rather than relying on ventilation alone.

Can AQ1w tell me exactly what is causing poor air quality?

No. Aq1w measures several indicators of indoor air quality, but it does not identify specific pollutants or their sources. For example, a high TVOC reading indicates an increase in the sensor’s TVOC measurement, but it does not identify which chemical is present. Similarly, particulate measurements do not identify the source of the particles.

Use the readings together with your knowledge of activities and conditions in the space to help investigate possible sources.

Still Need Help?